Source: Time:2022-08-10 22:40:36 views:

Simple Troubleshooting Methods for Metal Detectors

Simple Troubleshooting Methods for Metal Detectors


1. Conveyor belt deviation

    1) Determine whether the tension of the conveyor belt is appropriate. If the conveyor belt is too loose, it is easy to deviate.

    2) On the pallet bracket of the conveyor belt, there are two adjustment bolts near the outlet end of the conveyor belt, through which the tension of the conveyor belt can be adjusted.

    3) Observe whether the tension of the two sides is consistent. If the tension of both sides is inconsistent, it will also cause the conveyor belt to deviate.

    4) Adjust the tension of the two belts to the same level through these two adjusting bolts to solve the problem of conveyor belt deviation.


2. The instrument has no sensitivity


    1) Check whether there are large metal foreign objects in the probe hole, such as coins, keys, screws, etc., and remove metal impurities.

    2) Whether the product selection is correct.

    3) Whether it is selected to be in the NG prohibited state, in this state, the instrument will not perform alarm and elimination actions when it detects any metal, but the signal indicator will indicate.

    4) If the above conditions are ruled out and the instrument still has no detection sensitivity, please call our company.


3. The instrument periodically false alarm


    1) Whether the conveyor belt is contaminated by metal impurities, if the conveyor belt is contaminated by metal impurities, the detector will alarm whenever the contaminated part passes through the detection area. Clean the conveyor belt to remove metal impurities.

    2) Even if the conveyor belt does not rotate, the instrument still periodically falsely alarms. At this time, there may be a high-power interference source around the detector, such as a vibrating screen.


4. The instrument alarms irregularly


    1) The detector occasionally has irregular false alarms, which may be caused by unstable power supply. This can be solved by adding a regulated power supply.

    2) When the product is not detected, the instrument is normal. When the product to be detected passes through the detection area, it still alarms even if the product does not contain metal impurities, which indicates that the detection parameters are not properly adjusted. Please refer to Chapter 3.

    3) If there is still a false alarm after the conveyor belt stops, check whether there are high-power interference sources around the equipment, such as motors, engines, etc.

    4) Check for large pieces of moving metal around the device.

    5) Check whether the grounding wire of the power supply is in good condition. In order to ensure the stable operation of the instrument, a solid grounding wire is required.


5. The motor does not start


    1) On the control box panel, lightly press the "Start" and "Stop" buttons to observe whether the relays in the control module are active. If there is any action, the motor is damaged or the starting capacitor is damaged. You can buy the same type of motor and replace it. Or contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization to prevent the danger of electric shock.

    2) If the relay does not act, the control module may be damaged, or the connecting wire may be loose. Eliminate the loose connection cable and observe whether the fault is eliminated. If the motor still does not start, please also contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization, in order to prevent improper repair and damage to other parts.


6. The product passes through the detector head, and there is no metal impurities, and the alarm is also issued


    1). When the product passes through the detector head, and there is no metal impurities, it will also alarm, indicating that the detection parameters are not properly debugged.

    2). Check whether it is a product that has been debugged. If the detection product is not set, you need to re-debug the detection parameters


Links
亚洲精品一区久久久久一品av| 亚洲第一无码AV无码专区| 日韩精品无码中文字幕电影| 亚洲精品人成无码中文毛片 | 91香蕉丝瓜榴莲污污网站| 久久精彩| 按着腰进入做到哭h| 免费日韩av| 日本老肥婆bbbwbbbwzr| WWW久久无码天堂MV| 亚洲无日韩码精品| 天天澡天天添天天摸97影院| 国产精品另类激情久久久免费| 亚洲啪啪综合AV一区| 亚洲精品一二区| www.xxoo色黄av| 岛国毛片| 国产精品成人99久久久久| 中文字幕av无码专区第一页| 精品日韩欧美一区二区在线播放| 无码丰满熟妇一区二区浪| 性色AV 一区二区三区| 色婷五月天| 97久久碰国产精品2023| 女人张开腿让男人桶爽| 国产精品制服丝袜无码| 无遮挡A级毛片免费看| 精品少妇爆乳无码AⅤ区| 97成人碰碰久久人人超级碰OO| 欧美日韩91| 色噜噜噜噜噜| 亚洲乱码日产精品BD| 欧美噜噜久久久xxx| 亚洲中字幕日产AV片在线| 亚洲中文字幕在线观看| 野外妇女被弄得流白浆| 久久精品国产WWW456C0M| 伊人网综合| 免费亚洲婷婷| 无码少妇一区二区三区视频| a级毛片免费完整视频|